TM3SAFL5R Modicon 2-Function Safety Module, 3 Outputs
- MFR #:
- TM3SAFL5R
- UPC:
- 785901970446
- Item #:
- 637784
TM3SAFL5R Modicon 2-Function Safety Module, 3 Outputs
- MFR #:
- TM3SAFL5R
- UPC:
- 785901970446
- Item #:
- 637784
Product Details
This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches and light curtains to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry.
Manuals and Documentation
Features
- Complete your Modicon M2xx PLC configuration with a dedicated safety I/O, no need to use a complete safety controller
- Modularity and easness of installation
- Removable terminals for easier and better control wires tightening, thus improving installation reliability
- Modicon TM3 is an EcoStruxure Machine I/O system
- Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism
Specifications
Identifiers
| Manufacturer Part Number |
TM3SAFL5R
|
|---|---|
| GTIN |
03606485393018
|
| UPC |
785901970446
|
|---|---|
| EAN |
3606485393018
|
General Information
| Manufacturer |
Schneider Electric
|
|---|---|
| Brand |
Schneider Electric
|
| Country Of Origin |
DE
|
| Standards Approvals |
Can reach PL d/category 3 ISO 13849-1 2008;can reach PL d/category 3 ISO 13849-2 2012;can reach SILCL 2 IEC 62061 2005;can reach SIL 2 IEC 61508 2010;TÜV;RCM;ANSI Haz Loc Class 1 Division 2 (pending);CSA Haz Loc Class 1 Division 2 (pending);EAC;CSA 61010-2-201 (pending);UL 61010-2-201;ISO 13849-1:2008;ISO 13849-2:2012;IEC 62061:2005;IEC 61508:2010;IEC 60947-5-1:2010;IEC 61131-2:2007;IEC 60204-1:2005;IEC 60204-1:2009/A1;IEC 61010-1:2010;EN 50581:2012;Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3;magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8;electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4;1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5;conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6;;CE;EFUP 10;UL;CSA;EAC;RCM;TÜV
|
|---|---|
| Application |
For emergency stop, switch and safety light curtain monitoring
|
Dimensions
| Dimensions |
1.72 in W x 2.87 in D x 3.7 in H
|
|---|
Technical Information
| Amperage Rating |
100 mA
|
|---|---|
| Number Of Outputs |
3
|
| Temperature Rating |
-10 to 55 deg C Horizontal Installation
|
| Terminal Type |
Screw
|
|---|---|
| Type |
2-Function
|
| Voltage Rating |
24 V DC
|