safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, screw, 24V DC

MFR: Schneider Electric
MFR #: TM3SAC5R
Item #: 607859

safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, screw, 24V DC

MFR #: TM3SAC5R
Item #: 607859
Availability
Location Available Qty
Available Available to Order
$465.99 each

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Catalog Number
TM3SAC5R
Manufacturer
Schneider Electric
Brand
Schneider Electric
Country of Origin
United States
Made in USA
Yes
Application
For emergency stop and switch monitoring
Display
for user 6 LEDs (green/red)
Mounting
Wall
Output Signal
10 V relay output;Relay instantaneous opening, 3 NO, potential free
Power Supply
100 mA 24 V DC external supply at state on);24 V - 15...20 % DC
Special Features
Emergency stop monitoring 1-channel wiring;emergency stop monitoring 2-channel wiring;monitoring of a movable guard with 2 switches and automatic start
Standard
Can reach PL d/category 3 ISO 13849-1 2008;can reach PL d/category 3 ISO 13849-2 2012;can reach SILCL 2 IEC 62061 2005;can reach SIL 2 IEC 61508 2010;TÜV;CSA 61010-2-201 (pending);CSA Haz Loc Class 1 Division 2 (pending);RCM;ANSI Haz Loc Class 1 Division 2 (pending);EAC;UL 61010-2-201;ISO 13849-1:2008;ISO 13849-2:2012;IEC 62061:2005;IEC 61508:2010;IEC 60947-5-1:2010;IEC 61131-2:2007;IEC 60204-1:2005;IEC 60204-1:2009/A1;IEC 61010-1:2010;EN 50581:2012;Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2;electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2;susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3;susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3;magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8;electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4;electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4;1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5;conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6;;EFUP 10;RCM;CSA;UL;TÜV;CE;EAC
GTIN
03606485392974
Item Type
Safety module