Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 2 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 7-1/2 in L x 3-1/2 in W

MFR: Appleton Electric
MFR #: EYSEF200
UPC: 781381694339
Item #: 144743

Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 2 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 7-1/2 in L x 3-1/2 in W

MFR #: EYSEF200
UPC: 781381694339
Item #: 144743
Availability
Location Available Qty
Available Available to Order
$295.01 each

UNILETS EY Series 40 PCT Expanded Fill Vertical And Horizontal Conduit Sealing Fitting, Size: 2 IN, Material: Malleable Iron, Finish: Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat), Connection: Female Threaded, Turning Radius: 2.63 IN, Length: 7-1/2 IN, Width: 3-1/2 IN, Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D, Class II, Groups E, F, G, And Class III, For Use With Threaded Rigid Metal Conduit and IMC

Manuals and Documentation
Features
  • Explosion proof, dust-ignition proof and raintight
  • Smooth, rounded integral bushing in each hub
  • Accurately tapped, tapered threads for tight
  • Allow up to 40% conduit fill in compliance with the National Electrical Code (NEC)
Catalog Number
EYSEF200
Manufacturer
Appleton Electric
Brand
Appleton
Sub Brand
UNILETS
Country of Origin
Mexico
Made in USA
No
Application
For Use With Threaded Rigid Metal Conduit and IMC
Connection
Female Threaded
Finish
Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat)
Material
Malleable Iron
Special Features
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; A
Standard
UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D; Class II, Groups E, F, G; And Class III
RoHS Indicator
No
UPC
781381694339
GTIN
00781381694339
Item Type
EY Series 40 PCT Expanded Fill Vertical And Horizontal Conduit Sealing Fitting
Length
9.3000
Length UOM
Inch
Width
5.8000
Width UOM
Inch
Height
4.6000
Height UOM
Inch
Weight
9.640
Weight UOM
Pounds
Size
2